As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ETOPS - AFTER SHUTTING DOWN #1 ENGINE HP VALVE NOT CLOSED. IT CONTINUED RUN. FADEC SYSTEM TEST, NO FAULTS DETECTED. REPLACED #1 EVIMU PER ASM 73-25-04 AND AWM 73-25-34. NO HELP #1 ENGINE CONTINUES TO RUN AFTER MASTER SWITCH OFF. SWAPPED BACKED ORGINAL EVIMU. FOUND PINS AT CONNECTOR 4071KS-C WORN. REPLACED PINS AND CONNECTOR AT 4071KS-C PER AMM 70-71-20. ENGINE RUN PENDING. PERFORMED ENG #1 RUN 3X. NO DEFECTS NOTED. NO FAULTS NOTED. OK FOR SVC.