What was found
ETOPS - BLOCK TURNBACK DUE TO ENG FAULTS. REPLACED FMU (ENG #1) PER AMM 73-21-52-000-802-A & 73-21-52-400-802A. OPS + LEAK CHECK OKAY. ALL FAULTS EXTINGUISHED. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - BLOCK TURNBACK DUE TO ENG FAULTS. REPLACED FMU (ENG #1) PER AMM 73-21-52-000-802-A & 73-21-52-400-802A. OPS + LEAK CHECK OKAY. ALL FAULTS EXTINGUISHED. OK FOR SERVICE.