What was found
ETOPS - ENG 2 IGN A FAULT DURING START. REMOVED AND REPLACED IGN A IGNITER PLUG ON ENG 2 PER AMM 74-21-01. OPS CHECK GOOD. NO DEFECTS NOTED. OK FOR SERVICE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - ENG 2 IGN A FAULT DURING START. REMOVED AND REPLACED IGN A IGNITER PLUG ON ENG 2 PER AMM 74-21-01. OPS CHECK GOOD. NO DEFECTS NOTED. OK FOR SERVICE