ETOPS - ENG 2 FADEC SYS FAULT ON ECAM. REMOVED AND REPLACED ENG2 EEC PER AMM 73-21-01, OPS CHECK GOOD NO FAULT NOTED ON ECAM. A/C OK FOR SERVICE