What was found
C/H STATION 1260 STRINGER NR 9 HAS LEVEL 2 CORROSION. REMOVED DAMAGED SECTION, FABRICATED SPLICE AND NEW LONGERON SECTION AND INSTALLED PER SRM 53-02 FIG 18 AND 51-30-0. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C/H STATION 1260 STRINGER NR 9 HAS LEVEL 2 CORROSION. REMOVED DAMAGED SECTION, FABRICATED SPLICE AND NEW LONGERON SECTION AND INSTALLED PER SRM 53-02 FIG 18 AND 51-30-0. (M)