Service difficulty report · Heat Exchanger · Doug DC1010

Difficulty date
September 12, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N160AA
Make and model
Doug DC1010
Aircraft serial
46710
Part
Heat Exchanger
Condition
Damaged
Location
Nr 3 Pack
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HNL - FLT 26 - E-6 LOG PAGE NR 4102029. AIRCRAFT MADE AIR TURN-BACK TO HNL. NR 3 MANIFOLD FAIL ILLUMINATED DURING CLIMB. NOTE: MANIFOLD PRESSURE, 45 PSI. MANIFOLD TEMPERATURE, 275 DEGREES. LIGHT REMAINED ON FOR 3 MINUTES AFTER PNEU SUPPLY DETECTOR SWITCH OFF. FOUND NR 3 PACK HEAT EXCHANGER DUCT MOUNTS DAMAGED. REMOVED AND REPLACED NR 3 HEAT EXCHANGER. LEAK CHECK AND OP CHECK GOOD. (X)