What was found
DURING C-CHECK INSPECTION, FOUND CRACK IN RADIUS OF FRAME TO SKIN ANGLE, FWD OF CAPTAINS WINDSHIELD, APPROX FS 83 BY 9. FABRICATED AND INSTALLED TWO DOUBLERS FROM 7075-T6 .090 INCH PER SRM 53-03 FIG 34. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION, FOUND CRACK IN RADIUS OF FRAME TO SKIN ANGLE, FWD OF CAPTAINS WINDSHIELD, APPROX FS 83 BY 9. FABRICATED AND INSTALLED TWO DOUBLERS FROM 7075-T6 .090 INCH PER SRM 53-03 FIG 34. (M)