What was found
AFT CARGO PIT FLOOR PANEL STATION 1047 HAS LEVEL 2 CORROSION ON ATTACH DOUBLERS AND 'U' CHANNELS HAVE DOUBLER HOLES, WORN/PULLED FASTENERS. 'U' CHANNELS AND ATTACH DOUBLERS HAVE LEVEL 1 CORROSION ON SKIN. FABRICATED AND INSTALLED NEW SUPPORT RIBS. U-CHANNELS AND CLIPS PER SRM 51-10-2, 51-10-3, 51-30-2. (M)