What was found
HNL - EVIDENCE OF LIGHTING STRIKE ON LEFT ELEVATOR TRAILING EDGE NEAR OUTBOARD STATIC WICK UNDERSIDE. PERFORMED LIGHTING STRIKE INSPECTION PER MM 5-53-0, TOP OF FUSELAGE FROM LEFT WINDOW BELT TO RT WINDOW BELT PEND AND 2B, 5 AND 6. COMPLETED LIGHTING STRIKE INSPECTION PER MM 5-53-0. FOUND STATIC WICK BAD. REPLACED STATIC WICK, OPS CHECK GOOD. (M)