Service difficulty report · Sensor · Doug DC1030

Difficulty date
January 10, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N140AA
Make and model
Doug DC1030
Aircraft serial
46712
Part
Sensor
Condition
Failed
Location
Nr 1 System
Stage of operation
CR
Nature of condition
M
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HNL - FLT 01 - LOG PAGE: 4917190. NR 1 MANIFOLD FAIL AT 1730, COMP FIRST CLASS WAS VERY WARM, MANIFOLD TEMP WAS 240 DEGREES, THEN CAME 'DUCT, AVIONICS COMP OVERHEAT' CAME ON. ACCOMPLISHED CHECKLIST. PNEUMATIC TEMP HIGH WARNING LIGHT ILLUMINATED. EMERGENCY CHECKLIST COMPLETED. PACK SHUT DOWN. REPLACED HIGH RPESSURE, BLEED TEMP SENSOR. GROUND RUN CHECK OK. (X)