What was found
HNL - FLT 466 - AFTER LANDING SLAT YELLOW DISAGREE LIGHT REMAINED ON AFTER RETRACTING FLAPS. RECYCLED FLAPS TO 50 DEGREES AND BACK AND LIGHT REMAINED ON. SECURITY AND CONDITION OF SLAT CHECKED OK. CHECKED SLAT SENSORS CHECKED OK. CHECKED SLAT HANDLE SWITCH CHECKED OK. BITE CHECK PROX BOX, CHECKED OK. OPERATED SLAT AND FLAP NUMEROUS TIMES, COULD NOT DUPLICATE AT THIS TIME. OK FOR SERVICE. (M)