What was found
TUL - DURING CHECK FOUND FUSELAGE FRAME CORRODED AT THE FORWARD LAVATORY SERVICE PANEL 9 INCHES BY 2 INCHES AT FORWARD E/E STATION 410. DEPTH IS .063. FRAME SPLICED WITH FILLER PLATE INSTALLED PER ESO 7349, DATED 3/12/99. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - DURING CHECK FOUND FUSELAGE FRAME CORRODED AT THE FORWARD LAVATORY SERVICE PANEL 9 INCHES BY 2 INCHES AT FORWARD E/E STATION 410. DEPTH IS .063. FRAME SPLICED WITH FILLER PLATE INSTALLED PER ESO 7349, DATED 3/12/99. (M)