What was found
CABLES NR P7A8 AND NR P7B8 IN THE CIRCUIT BREAKER PANEL AREA HAVE TERMINALS CRACKED. (REF: DESIGNATOR 2TB1) DUE TO THE STRESSES PUT ON THE CABLES DURING THE OPENING AND CLOSING OF THE OVERHEAD CIRCUIT BREAKER PANEL. THE TERMINAL ENDS COULD POSSIBLY SEVER CAUSING A MAJOR POWER FAILURE. ANOTHER POSSIBILITY IS THAT ONE CABLE COULD FAIL AND CONTACT THE AIRFRAME PRODUCING SEVERE ARCING. REPLACED AFFECTED TERMINAL ENDS.