Service difficulty report · Relay · Skrsky S76A

Difficulty date
November 12, 1998
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N2743E
Make and model
Skrsky S76A
Aircraft serial
760155
Part
Relay
Part number
A1077D
Condition
Failed
Location
Dc System
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RELAY INSTALLED ON AIRCRAFT. FOUND TERMINALS 12 AND 13 AND TERMINALS 22 AND 23 HAD NO CONTINUITY IN REST POSITION. WHEN POWER IS APPLIED TO X1 AND X2, THEY HAVE CONTINUITY. FUNCTIONAL CHECKED RELAY AS RECEIVED. CONFIRMED PROBLEM. RELAY WAS INADVERTENTLY WIRED IN REVERSE. HOWEVER, RELAY WAS SCRAPPED DUE TO TWO MOUNTING FLANGES WERE CUT OFF TO FACILITATE EASE OF INSTALLATION.