What was found
UNCOMMANDED FLOAT INFLATION. AT TIME OF INFLATION, AIRCRAFT HAD BEEN SHUT DOWN FOR TWO HOURS, THE BATTERIES WERE OFF, THE MANUAL INFLATION HANDLE WAS IN THE DOWN AND SAFTIED POSITION. INSPECTED AIRCRAFT INFLATION RIGGING, FOUND OK. ELECTRICAL SQUIB HAD NOT BEEN ACTIVATED. REPLACED FLOAT INFLATION VALVE ASSY AND RESERVICED FLOAT BOTTLE.