What was found
FM BLEEDS INTO ICS. FOUND VOLUME AND TRANSMIT KNOBS, SWITCH S1, AND LIGHT PANEL BAD. RESOLDERED BROKEN WIRE IN LIGHT PANEL AND REPLACED VOLUME AND TRANSMIT KNOBS AND SWITCH S1. REPAIRED. BENCH CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FM BLEEDS INTO ICS. FOUND VOLUME AND TRANSMIT KNOBS, SWITCH S1, AND LIGHT PANEL BAD. RESOLDERED BROKEN WIRE IN LIGHT PANEL AND REPLACED VOLUME AND TRANSMIT KNOBS AND SWITCH S1. REPAIRED. BENCH CHECK GOOD.