- Difficulty date
- January 15, 2003
- Submitted
- January 20, 2003
- Operation
- Air carrier
- Aircraft
- N612PH
- Make and model
- Bell 407
- Aircraft serial
- 53199
- Aircraft time
- 2,772 hours
- Engine
- Allsn 250C*
- Part
- Bleed Valve
- Part number
- 23005366
- Part serial
- FF58628
- Condition
- Malfunctioned
- Location
- Engine
- Stage of operation
- IN
- How discovered
- 9
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MGT HIGH ABOVE 3000 FEET AT CRUISE. REPLACED BLEED VALVE.
More about the Bell 407