What was found
TRANSPONDER INOPERATIVE. PERFORMED PRELIMINARY INSPECTION, FOUND DIODES CR204 & CR205 SHORTED. ALSO FOUND C214 CAPACITOR BAD. REPLACED CR204, CR205, C214. REPAIRED. ALSO REPLACED PHOTOCELL V101 AND PHOTOCELL LENS P/N 088-00548-0000 AND RETAINING RING P/N 090-0036-04.REPAIRED. BENCH CHECK GOOD.