What was found
IN WING BOX, UNDER ACCESS PANEL 261 FT BRACKET ANGLE BETWEEN LT STRINGER 2 AND WING BOX FRAME AT FS 369.511 FOUND CRACKED. REPLACED WITH NEW PN 85350270-101 IAW SRM 51-40-00 CRACK MINOR IN NATURE, NON STRUCTURAL IN TYPE. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IN WING BOX, UNDER ACCESS PANEL 261 FT BRACKET ANGLE BETWEEN LT STRINGER 2 AND WING BOX FRAME AT FS 369.511 FOUND CRACKED. REPLACED WITH NEW PN 85350270-101 IAW SRM 51-40-00 CRACK MINOR IN NATURE, NON STRUCTURAL IN TYPE. (K)