What was found
DURING TAKEOFF ROLL, THE LEFT AC BUS CAUTION LIGHT ILLUMINATED. CREW ABORTED TAKEOFF. FOUND DEICE FLUID CONTAMINATION IN NR 1 AC GENERATOR CONNECTOR. CLEANED CONNECTOR. ALSO REPLACED NR 1 AC GEN CONTROL UNIT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING TAKEOFF ROLL, THE LEFT AC BUS CAUTION LIGHT ILLUMINATED. CREW ABORTED TAKEOFF. FOUND DEICE FLUID CONTAMINATION IN NR 1 AC GENERATOR CONNECTOR. CLEANED CONNECTOR. ALSO REPLACED NR 1 AC GEN CONTROL UNIT.