NR 1 BLEED HOT CAUTION LIGHT WENT ON AND OFF AT 3000 FEET WITH ODOR FROM DUCTS. SELECTED NR 1 BLEED OFF AND LIGHT WENT OFF BUT ODOR DID NOT DISSIPATE. REMOVED AND REPLACED NR 1 H/P BLEED SOV IAW AMM 21-11-16, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 BLEED HOT CAUTION LIGHT WENT ON AND OFF AT 3000 FEET WITH ODOR FROM DUCTS. SELECTED NR 1 BLEED OFF AND LIGHT WENT OFF BUT ODOR DID NOT DISSIPATE. REMOVED AND REPLACED NR 1 H/P BLEED SOV IAW AMM 21-11-16, OPS CHECK GOOD.