What was found
ABORTED TAKEOFF, TAKEOFF WARNING HORN SOUNDED WHEN ADVANCING POWER LEVERS, CYCLED FLAPS, OPS CHECKED NORMAL. COULD NOT DUPLICATE ON GROUND RUN. R & R FLAP POSITION INDICATOR. OPS CHECKED GOOD IAW 27-53-05. GROUND RAN ACFT AFTER FLAP INDICATOR REMOVAL AND REPLACEMENT. ALL TAKEOFF PARAMETERS FUNCTION NORMAL WHEN IN AND OUT. ACFT OK FOR SERVICE.