What was found
RIB AT X222, STRINGER 30-31 HAS CORROSION. REMOVED VERTICAL FLOOR SUPPORT FRAME. REMOVED RIB SECTION AT X222 BETWEEN STRINGERS 32P AND 28S. COMPLIED WITH HFEC INSPECTION, NO DEFECTS NOTED. SPLICE FRAME AT X222 IAW EO8-53-11-0289.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIB AT X222, STRINGER 30-31 HAS CORROSION. REMOVED VERTICAL FLOOR SUPPORT FRAME. REMOVED RIB SECTION AT X222 BETWEEN STRINGERS 32P AND 28S. COMPLIED WITH HFEC INSPECTION, NO DEFECTS NOTED. SPLICE FRAME AT X222 IAW EO8-53-11-0289.