As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB RT AC BUSS C/L ILLUMINATED, ASSOCIATED WITH RT ELEVATOR HORN HEAT, RT STALL WARNING C/L, AND RT TRU C/L. OCCURRED APPROX 1 MIN AFTER SELECTING ICING SYS ON. INSPECTED NR 2 AC CONTACTOR BOX & NR 2 AC GEN. NO DEFECTS NOTED. R & R NR 2 BRUSH BLOCK IAW 61-10-11. GROUND RAN ACFT. OPERATED VARIOUS AC SYS, OPS CHECK GOOD.