What was found
LEFT AC "B" PHASE HAS ZERO LOADS AND VOLTS. LT STALL WARNING CAUTION LIGHT. LT PROP "B" PHASE ADVISORY LIGHT DID NOT INDICATE WHEN SELECTED ON. R & R NR 1 AC GENERATOR, GCU AND NR 1 BRUSH BLOCK IAW WC 24-20-11R AND WC 30-61-00. CHECKED GOOD.