What was found
RIGHT AC BUSS CAUTION LIGHT ILLUMINATED IN FLIGHT WITH ASSOCIATED CAUTION LIGHTS. COULD NOT DUPLICTE ON GROUND RUN. FOUND PROP HEAT SELECTED ON AT THE TIME. INSPECTED WIRING AND CURRENT LIMITERS IN RT AC CONTACTOR BOX. NO DEFECTS NOTED. R & R NR 2 AC GENERATOR AND GCU IAW WORKCARD 24-20-011R. OPS AND LEAK CHECKED GOOD.