What was found
NR 1 AND NR 2 STALL SYS FAIL AND PUSHER FAIL CAUTION LIGHTS ILLUMINATED ON TAKEOFF ROLL. CYCLED CIRCUIT BREAKERS SWSP COMP 1 AND 2 OPS NORMAL AT THIS TIME. SYS NR 1 FAULTS: VANE 1-B, VANE 1-F, ASCB 1, ICE 1 OFF. SYS NR 2 FAULTS VANE 2, VANE 2-B, VANE 2-E, ASCB 2, ICE 2 OFF. ALL FAULTS CLEARED. COULD NOT DUPLICATE FAULT. SWSP SYS OPS CKS GOOD IAW WC 27-30-08Q. CLEAR MEL.