As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER ROTATION, NR 2 AC GENERATOR CAUTION LIGHT ILLUMINATED. AFTER THREE MINUTES, NR 2 AC GENERATOR HOT LIGHT ILLUMINATED. CYCLED GENERATOR OFF IAW CHECK LIST. OIL PRESSURE WAS FLOATING BETWEEN 45 AND 55. FEATHERED NR 2 ENGINE AND PRESSURE STABILIZED AT 50 PSI. R & R NR 2 ENGINE AND OIL COOLER IAW WC 71-00-01 AND 71-00-02.