As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 HYDRAULIC QTY SLOWLY DROPPED. ISOLATION LIGHT ILLUMINATED FOR APPROX 2 MINUTES, THEN EXTINGUISHED. ENGINE DRIVEN PUMP CAUTION LIGHT ILLUMINATED AND REMAINED ON. INSPECTED AND FOUND NR 2 ENGINE HYDRAULIC PUMP LEAKING. R & R PUMP IAW 72-00-04L. ALSO, R & R CASE DRAIN FILTER IAW 29-12-03R. SERVICED HYDRAULICS AND BLED SYSTEM. OPS AND LEAKED CHECKED GOOD.