Service difficulty report · Circuit Breaker · Dhav DHC8311

Difficulty date
May 27, 2016
Submitted
May 31, 2016
Operation
Air carrier
Aircraft
N335EN
Make and model
Dhav DHC8311
Aircraft serial
375
Aircraft time
48,807 hours, 54,180 cycles
Part
Circuit Breaker
Condition
Failed
Location
Boost Pump
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 AUXILIARY PUMP APPEARED NOT TO WORK. DISCONNECTED MAIN AND AUXILIARY BATTERY CONNECTORS. SHORT SIGNED 281933. FOUND CIRCUIT BREAKER NR 1 FUEL AUXILIARY PUMP BAD. RNR C/B 2821-CB1, NR 1 FUEL AUXILIARY PUMP, AUXILIARY PUMP, OPS CHECK GOOD RECONNECTED MAIN AND AUXILIARY BATTERY CONNECTORS, PN 335-29-11 1305913, CIRCUIT BREAKER, PN MS3320-5, NR 1 AUXILIARY PUMP APPEARED NOT TO WORK.