What was found
DURING CLIMB OUT AT ABOUT 11K, BOTH NR 1 HYDRAULIC ISO AND ROLL SPOILER INBOARD CAUTION LIGHTS ILLUMINATED WITH NR 1 HYDRAULIC QUANTITY RAPIDLY DROPPING TO .7 QUARTS. HYDRAULIC PRESSURE REMAINED AT 3000. NSPECTED AND FOUND PRESSURE FITTING ON NR 1 EDHP LOOSE AND LEAKING. REMOVED AND REPLACED THE O-RING AND INSPECTED CASE DRAIN HYDRAULIC FILTER. NO CONTAMINATION FOUND. SERVICED NR 1 HYDRAULIC QUANTITY . GROUND RAN GOOD. LEAKED CHECKED GOOD.