As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RAN QRH FOR A LEAK EICAS MESSAGE INFLIGHT AT 10000 FT. MESSAGE DID NOT EXTINGUISH. ALSO HAD A NR 2 BLEED VALVE CLOSED MESSAGE. INSPECTED AND FOUND GROUND AIR TEMPERATURE SWITCH SHORTED TO GROUND. CLEANED AND SEALED IAW AMM 20-30-03. PERFORMED BLEED AIR TEST IAW AMM.