What was found
NDIS 683 33-51 0001790 11DEC17 RIC CLOSE SERVICE DOOR EMERGENCY LIGHT WONT ILLUMINATE 28805 00 SJU FACT 11DEC17 08:17 RIC FOUND BROKEN WIRES W716-0007-20 AND W716-0008-20 REP LACED WIRES IAW SWPM 20-21-00 OPS CHECK GOOD OK FOR SERVICE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NDIS 683 33-51 0001790 11DEC17 RIC CLOSE SERVICE DOOR EMERGENCY LIGHT WONT ILLUMINATE 28805 00 SJU FACT 11DEC17 08:17 RIC FOUND BROKEN WIRES W716-0007-20 AND W716-0008-20 REP LACED WIRES IAW SWPM 20-21-00 OPS CHECK GOOD OK FOR SERVICE