What was found
GALLEY CROSSBEAM AT FRAME 20 CORRODED. INSTALLED 3 NUTPLATES ON GALLEY CROSSBEAM AT FRAME 20 IAW SRM 51-40-09.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GALLEY CROSSBEAM AT FRAME 20 CORRODED. INSTALLED 3 NUTPLATES ON GALLEY CROSSBEAM AT FRAME 20 IAW SRM 51-40-09.