Service difficulty report · Relay · Emb EMB145LR

Difficulty date
November 5, 2018
Submitted
November 8, 2018
Operation
Air carrier
Aircraft
N639AE
Make and model
Emb EMB145LR
Aircraft serial
145182
Aircraft time
44,228 hours, 40,391 cycles
Engine
Allsn AE3007A
Part
Relay
Condition
Malfunctioned
Location
Eng Anti Ice
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 639 30-21 1689141 05NOV18 PIT CLOSE E1 ANTI ICE VALVE FAIL MESSAGE DISPLAYED ACFT WAS IN ICING IN CLIMB. ALSO ADVISORY MSG E-ANTI ICE OVER PRESS DISPLAYED. C/W MX PROCEDURE FACT 05NOV18 06:04 ROA REACTIVATED E1 ANTI-ICE VALVE PER AMM TASK 30-21-440-801-A. R/R'D RELAY K0534 IAW AMM TASK 20-13-02-04, PERFORMED A-ICE OPERATIONAL TEST TASK 30-00-00-700-802-A OPS CK GOOD CLEAR MEL.