What was found
PDIS 682 36-20 1665443 29NOV18 ROA CLOSE BLEED 2 LOW TEMP EICAS MESSAGE WHILE IN ICEING CONDITIONS. INCREASED THRUST DID NOT CORRECT
HISTORY: NO FACT 29NOV18 17:37 ROA R&R FAN AIR VALVE IAW AMM 36-11-03. GROUND RAN BOTH ENGINES WITH PACKS ON , A/ICE SYS ON NO DEFECTS NOTE D OK FOR SERVICE.