What was found
NDIS 603 30-41 0020580 09FEB19 CLT CLOSE PLEASE FOLLOW UP WITH WIND SCREEN HEAT OPS CHECK FOR #2 W/S DUE TO OCCASIONAL OCCURANCES OF FAIL INDICATIONS THEN INSTANTLY CLEARING ITSELF AND OPERATING NORMALLY. DFRL 09FEB19 10:53 CLT PLEASE PERFORM OPS AND FUNCTION CHECK IN AMM 30-42-00-05. DFRL 12FEB19 09:11 SBY PERFORMED OPS CHECK AS REQUIRED. FOUND ZERO VOLTAGE AT PIN B ON WINDSHIELD HEAT CONTROLLER. FOUND BURN MARKS ON TERMINAL BLOCK ON CONTROLLER. REPAIRED PIN B TERMINAL RING REFERENCING SWPM 20-21-00. R&R' D WINDSHIELD HEAT CONTROLLER REFERENCING AMM 30-42-01. COMPLIED WITH HIDDEN DAMAGE INSPECTION P/N ON CONTROLLER 1300126, S/N ON 6019 P/N OFF CONTROLLER 1300126, S/N OFF 711