What was found
RH AFT EXTERIOR EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE.... FIX: R&R D RH AFT EMERGENCY LIGHT,OPS CHCK GOOD IAW AMM TASK 33-50-10-000/400-801-A
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RH AFT EXTERIOR EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE.... FIX: R&R D RH AFT EMERGENCY LIGHT,OPS CHCK GOOD IAW AMM TASK 33-50-10-000/400-801-A