Service difficulty report · Thermostat · Emb EMB145LR

Difficulty date
September 7, 2019
Submitted
September 9, 2019
Operation
Air carrier
Aircraft
N640AE
Make and model
Emb EMB145LR
Aircraft serial
145183
Aircraft time
44,633 hours, 41,059 cycles
Part
Thermostat
Condition
Malfunctioned
Location
Anti-Ice System
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 640 30-10 1826421 07SEP19 ART CLOSE DURING ICING, WG A/ICE FAIL MSG ON EICAS, CREW C/W QRH, MESSAGE CLEARED. FACT WING A/I LEAK MESSAGE ON CMC. FOUND BLEED PIPE BETWEEN PACK VLV #1 AND TEMP CONTROL VLV #1 TO BE LEAKING. R&R'D PIPE IRT AMM 21-60-01. LEAK CK GOOD. WING A/I THERMOSTAT ACTIVATES AT 130 DEGREES . R&R'D THERMOST AT PER AMM 30-11-05. PERFORMED A/I SYS OPS CK 30-00-00-700-802-A. OPS CK GOOD. CLEAR MEL.