Service difficulty report · Warning System · Emb EMB145LR

Difficulty date
September 12, 2019
Submitted
September 13, 2019
Operation
Air carrier
Aircraft
N626AE
Make and model
Emb EMB145LR
Aircraft serial
145117
Aircraft time
45,788 hours, 43,523 cycles
Part
Warning System
Condition
False Activation
Location
Cockpit
Stage of operation
TO
How discovered
O
Nature of condition
N
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 626 78-32 1830691 12SEP19 CLT CLOSE E1 T/R DISAGREE MSG DISPLAYED ON TAKEOFF ROLL. C/W MX PROCEDURE. NOTE CMC SHOWS E1 T/R VALVE FAIL. FACT 13SEP19 01:07 MDT REACTIVATED #1 T/R CND REF FIM TASK 78-34-00-810-804A,R&R'D RELAY K0641. OPERATED T/R'S SEVERAL TIMES, OPS CHECK GOOD.