Service difficulty report · Duct · Emb EMB145LR

Difficulty date
October 14, 2019
Submitted
October 15, 2019
Operation
Air carrier
Aircraft
N628AE
Make and model
Emb EMB145LR
Aircraft serial
145124
Aircraft time
45,799 hours, 42,921 cycles
Part
Duct
Condition
Detached
Location
Nr 2 A/C Pack
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED A SULFER OR ELECTRICAL ODOR IN THE COCKPIT DURING CRUISE AT 17K FT. NO ASSOCIATED EICAS MESSAGES. ODOR PERSISTED DURING DESCENT AND DISSIPATED ON LANDING. FOUND THAT WHEN RUNNING PACK NR 2, TEMP HAD A RUN AWAY TO FULL HOT IN AUTO MODE. FOUND PACK 2 DUCT DETACHED, REATTACHED THE DUCT AS REQUIRED. R & R PACK 2 DUCT TEMP SENSOR IAW AMM 21-60-03-000/400-801-A, R & R PACK 2 AMBIENT TEMP SENSOR IAW 21-60-02-000/400-801-A. R & R PACK 2 DIGITAL TEMP CONTROLLER IAW 21-60-04-000/400-801-A. OPS CHECKED GOOD ON GROUND.

More about the Emb EMB-145LR