Service difficulty report · Tube · Emb EMB145LR

Difficulty date
September 30, 2020
Submitted
October 1, 2020
Operation
Air carrier
Aircraft
N690AE
Make and model
Emb EMB145LR
Aircraft serial
14500858
Aircraft time
37,080 hours, 33,405 cycles
Part
Tube
Condition
Disconnected
Location
Control Valve
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDIS 690 36-21 2337261 30SEP20 ALB CLOSE. DURING CRUISE BLD 1 LEAK MESSAGE ON EICAS, CREW C/W QRH MSG GONE. FACT 01OCT20 03:28 ALB. FOUND TUBE TO BE DISCONNECTED ON DUAL TEMP CONTROL VALVE. INSTALLED TUBE AND R & R CLAMP, IAW EMB 145 AMM 21-60-01. PERFORMED AIR BLEED LEAK AND OPERATIONS CHECK IAW EMB 145 AMM 36-00-00. LEAK AND OPERATIONSS CHECK GOOD.