What was found
CARGO DOOR INTERIOR WEB FRAME HAS 8 CHAFES. BLENDED 8 EACH CHAFES ON INTERIOR WEB, IAW EMB 145 SRM 51-10--03. THE BLEND 12" FROM FWD EDGE AND 14"- FROM BOTTOM FOUND TO BE BEYOND LIMITS. PERFORMED CUTOUT OF DAMAGED AREA, FABRICATED DOUBLER. INSTALLED DOUBLER FOR REPAIR, IAW EMB 145 SRM 52-30-01RE AND PIEDMONT EO1-52-20-0371.