What was found
RT MLG AFT UPPER TRUNNION CRACKED OUTBD OF BEARING ABOVE 1ST FASTENER TO TRUNNION EDGE. EASI 6581 USED. 100-500KHZ PROBE, FREQ=400KHZ,V-GAIN=78.0, H-GAIN=65.0, LPF =100. REPAIR IS REMOVED AND INSTALLED SERVICEABLE RT MLG AFT TRUNNION, IAW TI TI-145-- 14-018 RH REV. G, ETD2020-145-029103 AND EO1-57-20-0379.