What was found
PERFORMED HFEC INSPECTION, IAW EASI NDTM RELEVANT INDICATION NOTED ON RT MLG AFT TRUNNION. ET EASI 8958 SETTINGS: FREQ. 400KHZ, ANGLE 291.1 DEG. H-61.3DB. V-77.6DB. FILTER LO PASS 500HZ. REMOVED AND REPLACED THE RT MLG AFT UPPER TRUNNION, IAW PIEDMONT EO1-57-20-0432.