What was found
DENT ON FUSELAGE SKIN BETWEEN FR 22-23 AND BETWEEN STR 12L-13L. INSTALLED AND EDGE SEALED SERVICEABLE REPAIR DOUBLER AND FILLER ON FUSELAGE SKIN BETWEEN FR 22-23 AND BETWEEN STR 12L-13L, IAW EMB 145 SRM 53-21-01, ITEM 5, FIGURE 202 AND EO1-53-20-0440.