Service difficulty report · Sensor · Emb EMB145LR

Difficulty date
December 28, 2020
Submitted
December 29, 2020
Operation
Air carrier
Aircraft
N644AE
Make and model
Emb EMB145LR
Aircraft serial
145204
Aircraft time
47,637 hours, 43,770 cycles
Part
Sensor
Condition
Faulted
Location
Nr 1 Temp
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLD 1 OVTEMP MESSAGE DURING ICE TEST IN FLIGHT, MESSAGE EXTINGUISHES AFTER TURNING OFF ICE PROTECTION. MX TROUBLESHOT, PER FIM 36-11-00-810-803-A. R & R CHANGED NR 1 AIR FILTER AND NR 1 TEMP SENSOR ON PYLON. PERFORMED BLEED SYSTEMS OPERATIONS CHECK SEVERAL TIMES. OPERATIONS CHECK GOOD, REF AMM36-00-00-05 AND 36-20-01-05 PN OFF 0132 ADT SN OFF E5273. PN ON 0132ADT SN ON P1190.

More about the Emb EMB-145LR