What was found
BLD 1 OVTEMP MESSAGE DURING ICE TEST IN FLIGHT, MESSAGE EXTINGUISHES AFTER TURNING OFF ICE PROTECTION. MX TROUBLESHOT, PER FIM 36-11-00-810-803-A. R & R CHANGED NR 1 AIR FILTER AND NR 1 TEMP SENSOR ON PYLON. PERFORMED BLEED SYSTEMS OPERATIONS CHECK SEVERAL TIMES. OPERATIONS CHECK GOOD, REF AMM36-00-00-05 AND 36-20-01-05 PN OFF 0132 ADT SN OFF E5273. PN ON 0132ADT SN ON P1190.