What was found
CABIN CEILING EMERGENCY EXIT AFT SIGN LIGHT DOES NOT TURN ON. RESET C/B NO FIX. REMOVED LT CABIN FLOOR PANEL 251JF TO ACCESS EMERGENCY BATTERY RESEATED NR 3 EMERGENCY BATTERY CANNON PLUG. OPERATIONS CHECK GOOD INSTALLED FLOOR PANEL 251JF USING RETAINED HARDWARE OK FOR SERVICE AT THIS TIME PERFORMED. OPERATIONS CHECK, IAW W/C 33-70-17.