What was found
PDIS 632 27-36 2379001 01JUN21 EVV CLOSE SPS 1-2 INOP, SPS ADANCE, NO TAKEOFF CONFIG DURING TAKEOFF MESSAGES CLEARED WHEN A/C STOPPING. FACT 01JUN21 10:52 EVV PERFORMED SPS OPS CHECK IAW AMM 27-36-00-700-801-A. OPS CHECK GOOD. NO SPS MSGS DISPLAYED ON EICAS, A/C OK FOR SERVICE AT THIS TIME.