What was found
EMERGENCY LIGHT BULBS AT MAIN DOOR WILL NOT ILLUMINATE. WHILE REMOVING PANEL 811XW NOTICED WIRE BROKEN ON EMERGENCY LIGHT ASSY AT MAIN DOOR. CRIMPED NEW CONTACT AND CONNECTED AT SP7425 REF SWPM 20-50-01. REINSTALLED PANEL 811XW AS REQ. OPS CHECK ON MAIN DOOR EMERGENCY LIGHT IAW AMM 33-50-00-700-801-A/500 OP CHECK GOOD. NO DEFECTS NOTED AT THIS TIME OK FOR SERVICE.